Condição de TCF-142-S-ST: novo em embalagem comercial
Outros Part Numbers para este componente: TCF142-S-ST The TCF142 media converter is equipped with a multiple interface circuit that can handle RS232 or RS422/485 serial interfaces and multimode or singlemode fiber. TCF142 converters are used to extend serial transmission up to 5 km (TCF142M with multimode fiber) or up to 40 km (TCF142S with singlemode fiber). The TCF142 can be configured to convert either RS232 signals, or RS422/485 signals, but not both at the same time.
Automatic Baudrate Detection
The TCF142 can automatically detect the serial baudrate. This is an extremely convenient feature. Even if a devices baudrate is changed, the signal will still be transmitted through the media converter without any data loss.
Ring Operation
The TCF142 converters can be used to connect serial devices to a fiber ring. To form the ring, connect the Tx port of one TCF142 to the Rx port of a neighboring converter. Once the ring is set up, simply use the DIP switches to configure the TCF142 converters for ring mode. When one node transmits a signal, the signal travels around the ring until it xxs back to the transmitting unit, which then blocks the signal. With the TCF142, you can set up fiber rings that have a total circumference of up to 100 km.
Automatic Data Direction Control (ADDC)
ADDC is a patented hardware data flow solution developed by Moxa to handle RS485 data direction control. ADDC senses and controls RS485 data direction automatically, making it unnecessary to use the hand shaking signal.
Features
Ring and PointtoPoint transmission
Extends RS232/422/485 transmission up to:
40 km with singlemodeTCF142S
5 km with multimodeTCF142M
Compact size
Decreases signal interference
Protects against electrical interference and chemical corrosion
Supports baudrates of 50 bps to 921.6 Kbps
Wide temperature models available (40 to 75C)
Optical Fiber Side
Fiber Connector SC or ST
Cable Requirements Singlemode: 8.3/125, 8.7/125, 9/125, or 10/125 m
Multimode: 50/125, 62.5/125, or 100/140 m
Transmission Distance Singlemode: 40 km
Multimode: 5 km
Wavelength Singlemode: 1310 nm
Multimode: 850 nm
Tx Output Singlemode: > 5 dBm
Multimode: > 5 dBm
Rx Sensitivity Singlemode: 25 dBm
Multimode: 20 dBm
PointtoPoint Transmission Halfduplex or fullduplex
Ring Transmission Halfduplex
RS232/422/485 Side
Connector Terminal Block
RS232 Signals Tx, Rx, GND
RS422 Signals TxD , TxD, RxD , RxD, GND
RS4854w Signals TxD , TxD, RxD , RxD, GND
RS4852w Signals Data , Data, GND
Baudrate 50 bps to 921.6 Kbps
ESD Protection 15 KV for all signals
Physical Characteristics
Housing Aluminum (1 mm)
Dimensions Without ears: 67 x 100 x 22 mm (2.64 x 3.94 x 0.87 in)
With ears: 90 x 100 x 22 mm (3.54 x 3.94 x 0.87 in)
Weight 320 g
Environmental Limits
Operating Temperature Standard Models: 0 to 60C (32 to 140F)
Wide Temp. Models: 40 to 75C (40 to 167F)
Storage Temperature 40 to 75C (40 to 167F)
Ambient Relative Humidity 5 to 95% (noncondensing)
Power Requirements
Input Voltage 12 to 48 VDC
Power Consumption 140 mA @ 12 V
Power Line Protection 2 KV Burst (EFT), EN6100044
2 KV Surge, EN6100045
Voltage Reversal Protection Protects against V /V reversal
Over Current Protection 1.1 A (protects against two signals shorted together)
Standards and Certifications
Safety UL 609501
EMC CE, FCC
EMI FCC Part 15 Subpart B Class B, EN 55022 Class B
EMS EN 6100042 (ESD) Level 3,
EN 6100043 (RS) Level 2,
EN 6100044 (EFT) Level 2,
EN 6100045 (Surge) Level 2,
EN 6100046 (CS) Level 2,
EN 6100048 (SFMF) Level 1
Green Product RoHS, CRoHS, WEEE
MTBF (mean time between failures)
Time 780,480 hrs
Database Telcordia (Bellcore), GB